Carriage travelCa. 0,14 m/sec with soft start and soft
stop
Pull and Push force 1000N.
Garage light Automatic shut off after ca.
180 seconds (adjustable 90 - 240 seconds), 1 x 40 W max., E14 light
bulb (not included)
Connected load 230 Volt, 0,30 KW for KSC230V-433Mhz.
Energy saving circuit Total
consumption of non-activated garage door operator is ca. 0,0039
KW.
Operating mode
Short period operation max. KB 2 min
Motor and transformer
Direct Current worm gear motor,
Mains regular current transformer with Thermal overload protection
Control unit Microprocessor controlled,
All-on-one circuit board principle, Personal Computer diagnostics
with special software is possible
Control unit voltage
Low voltage ca. 24 Volt
Output power for accessories: about 24 VDC, 50 mA max., short circuit
protected
Protection category Only
suitable for inside dry buildings (IP20)
Adjustment Simple
and easy 3 step programming: open
limit position, close limit position
and learn transmitter code. All other
parameters can be set with step by step menu; Optical sensor presence, independent open and close force, speed control, automatic closing and lighting features
Automatic cut out Electronic
force control by motor current control, Integrated self learning
force control with adjustable offset, Individual open and close
force setting in program menu, Automatic full door reverse when
detected obstruction under closing door
Packaging Individual packaging
for motor head and rail
Weights: motor head completely packaged: 5,50 Kg
standard chain channel RCD298-1P: 5,53 Kg
standard chain channel RCD320-1P: 5,68 Kg
standard chain channel RCD411-1P: 7,29 Kg
standard chain channel RCD320-2P: 5,97 Kg
standard belt channel RBD298-1P: 4,61 Kg
standard belt channel RBD320-1P: 4,74 Kg
standard belt channel RBD411-1P: 6,08 Kg
standard belt channel RBD320-2P: 4,98 Kg |
Display Operator status
or diagnostics displayed by 8 light diodes
Excess travel stop Security
cutout after 80 sec. travel time (adjustable 30 - 240 sec)
Block protection Additional
to automatic cut out, by microprocessor and RPM sensor
Back-drive guard Electronic
back-drive prevention by permanent protection of door closed position
(automatic close after ca. 1 cm. reversed movement)
Travel cut out
Electronic travel cut out by reference point processing
Automatic closing function
Integrated with adjustable warning and door open time. Warning time:
2 - 70 sec. Door open: 5-255 sec. Signal light connection by external
relays (not included)
Speed control
Electronic controlled soft stop and soft start
Digital
radio system (possible)
Transmitter with code learning
function and Multibit technology.
Receiver integrated on motor control
board. Self learning Multibit-coding
Frequency 868 or 433 MHz.
Housing Motor cover in shock
resistant ABS. 3-screw fastening. Snap-on/off lens cover (no screws).
Snap-on/off cover for wire terminal access; not required to remove
motor cover to access wire connections.
Rails and carriage 1-piece or
2-piece split C-channel pre-assembled rails Chain or belt system.
Durable anti-wear synthetic carriage with emergency release cord
with automatic engage system.
Installation parts (fittings)
Standard installation kit without screws for lintel and ceiling.
Includes: Z-style door arm, two mounting straps, extra rail/ceiling
support and screws for door bracket installation on steel doors.
All our products are CE certified.
Relevant European Council Directives pertaining to electromagnetic compatibility (89/336/EEC, 93/68/EEC and 93/44/EEC), machines (89/392/EEC, 91/368/EEC, 93/68/EEC and 93/44/EEC) and low voltage (73/23/EEC, 93/68/EEC and 93/44/EEC).
To agreed standards: EN292-1, EN12453, EN12445, EN50081-1, EN50082-1, EN55014, EN60335-1, EN60335-2-95, EN61000-3-2, EN61000-3-3, EN300220-1, EN 301489-3, ETS 300683, I-ETS 300200. To national standard and technical specification: ZH 494 April 89, VDE 0700-238
  |